|   | _HKI ("The goal of the IEC60664-1 is to provide guidance on designing insulation for products that have a connection to mains supply.\n" "\n" "However some cases are not covered by this calculator:\n" "\n" "- For frequencies higher than 30kHz, the dielectric performances are degraded. IEC60664-4 covers those cases\n" "- When using a conformal coating or a potting in order to protect for pollution, if all conditions specified by IEC60664-3 are met, the clearance and creepage distances can be reduced. Soldermask is usually not considered as a conformal coating.\n" "- Insulations trough liquids, compressed air or gases other than air are not in the scope of IEC60664") | 
|   | 
◆ _HKI()
      
        
          | _HKI  | 
          ( | 
          "The goal of the IEC60664-1 is to provide guidance on designing insulation for products that have a connection to mains supply.\n" "\n" "However some cases are not covered by this calculator:\n" "\n" "- For frequencies higher than |           30kHz,  | 
        
        
           | 
           | 
          the dielectric performances are degraded. IEC60664-4 covers those cases\n" "- When using a conformal coating or a potting in order to protect for |           pollution,  | 
        
        
           | 
           | 
          if all conditions specified by IEC60664-3 are |           met,  | 
        
        
           | 
           | 
          the clearance and creepage distances can be reduced. Soldermask is usually not considered as a conformal coating.\n" "- Insulations trough |           liquids,  | 
        
        
           | 
           | 
          compressed air or gases other than air are not in the scope of IEC60664" |            ) |