Go to the source code of this file.
|
| _HKI ("The goal of the IEC60664-1 is to provide guidance on designing insulation for products that have a connection to mains supply.\n" "\n" "However some cases are not covered by this calculator:\n" "\n" "- For frequencies higher than 30kHz, the dielectric perfomances are degraded. IEC60664-4 covers those cases\n" "- When using a conformal coating or a potting in order to protect for pollution, if all conditions specified by IEC60664-3 are met, the clearance and creepage distances can be reduced. Soldermask is usually not considered as a conformal coating.\n" "- Insulations trough liquids, compressed air or gases other than air are not in the scope of IEC60664") |
|
◆ _HKI()
_HKI |
( |
"The goal of the IEC60664-1 is to provide guidance on designing insulation for products that have a connection to mains supply.\n" "\n" "However some cases are not covered by this calculator:\n" "\n" "- For frequencies higher than |
30kHz, |
|
|
the dielectric perfomances are degraded. IEC60664-4 covers those cases\n" "- When using a conformal coating or a potting in order to protect for |
pollution, |
|
|
if all conditions specified by IEC60664-3 are |
met, |
|
|
the clearance and creepage distances can be reduced. Soldermask is usually not considered as a conformal coating.\n" "- Insulations trough |
liquids, |
|
|
compressed air or gases other than air are not in the scope of IEC60664" |
|
|
) |
| |