KiCad PCB EDA Suite
|
Which IPC-4761 via protection features can be built together. More...
Functions | |
| bool | CapAllowed (bool aFilled) |
| A cap is copper plated over a filled hole, so it needs the fill. | |
| bool | PlugAllowed (bool aFilled) |
| A plug is a partial fill from one side. A filled hole has nothing left to plug. | |
| bool | CoverAllowed (bool aFilled, bool aTented, bool aPlugged) |
| A cover is a second coat over a tent, a plug or a fill. | |
Which IPC-4761 via protection features can be built together.
Board Setup greys out what these rule out and the cross section preview does not draw it, so the two agree.
|
inline |
A cap is copper plated over a filled hole, so it needs the fill.
Definition at line 31 of file via_protection_rules.h.
Referenced by VIA_CROSS_SECTION_GEOMETRY::build(), and PANEL_SETUP_BOARD_FINISH::enableViaProtection().
|
inline |
A cover is a second coat over a tent, a plug or a fill.
IPC-4761 has no cover over an open hole, because a coat cannot float.
Definition at line 46 of file via_protection_rules.h.
Referenced by VIA_CROSS_SECTION_GEOMETRY::build(), and PANEL_SETUP_BOARD_FINISH::enableViaProtection().
|
inline |
A plug is a partial fill from one side. A filled hole has nothing left to plug.
Definition at line 38 of file via_protection_rules.h.
Referenced by VIA_CROSS_SECTION_GEOMETRY::build(), and PANEL_SETUP_BOARD_FINISH::enableViaProtection().